Mar 14

pool timer trippers not working

},
Some of the most common issues for a pool pump timer not working are: power outage, incorrectly positioned yellow clock wheel, loose timer trippers, faulty internal timer, and a worn-out motor. (For outside light timer) The one before was original to the house & I had no trouble. DEWENWILS Pool Pump Timer, Outdoor Smart Wi-Fi Box, Heavy Duty 40A 120-277 VAC 2HP Wireless Controller Timer for Pool, Water Heater, Compatible with Smart Phone, Alexa, Google Assistant, UL Listed. I also dont see any ants or other insects. If the power has gone out, your just opening your swimming pool for the season or some third reason, you may need to adjust the time on your Intermatic swimming pool timer. I have an intermatic T20004R and my timer is working because it is keeping the correct time. Hi DavyI just installed a new timer after being told by the pool inspector that the old one was dead. Is the timer repairable, or should I just install a new one? Phil. Step 3 Once you figure out what is wrong with the timer, you may be able to do the repair yourself or might have to hire an electrician to come and replace the timer for you. If the timer clock is not turning on your pool pump timer, its either the timer itself has a fault or theres no power to the timer. Pull the timer out and turn it to the correct time. If after verifying you have power to the timer, then check these things to further troubleshoot. I have the Intermatic T103 autotimer on my pool. Pop-in a new timer mechanism, and replace the wires to the previous configuration.
Flip it from where it is now, to the opposite side. Did you try to flip the switch of the timeclock? Jump to the troubleshooting steps below to fix the issue. We have a comprehensive article that covers what to do when the pump circuit breaker continually trips. Hi Jeremy, I would try to pull the unit out and clean it well with compressed air and then spray with WD-40 and see if that helps. Using a tester i noticed that there is no power going thru the lines for the pump and salt system. Terry, unusual but check all connections, making sure that bare wire is tightly contacting the terminal screw plates. To set it, you just move the on/off "trippers" where you want them. Are the gears engaged, in the center, behind the dial? it could also be a failing breaker, but that would be a last resort. Thanks Reid. Pool Timer Clock Parts and Trippers Welcome to Pool Spa Outpost! Intermatic time clocks are the workhorse of your pool equipment collection, and oftentimes outlive the equipment they control. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Assuming the wiring is all correct. A power surge may have taken out the timer or the pump. Filter pump is ON at all timer Timer contacts welded Replace timer 5 . The problem I am having is the timer clock moves correctly, but when it gets to the ON or OFF mark it stops and does not make the switch turn ON or OFF. Did somthing else maybe burnt out or what is a good troubleshooting I can do before I call an electrician. Now The ice and snow have melted and the cover is getting in deeper. It would not reset itself and could not get power back to the timer. Thanks for your help! This is the first step to confirm if there is power or not. The screw in the center point timer occasionally comes loose due to vibrations from the pump and filter. Is the dial bent or warped? 1-48 of 242 results for "pool timer trippers" RESULTS. Any idea what may be causing this? If your 120V wires are properly colored, the White wire connects to terminal A, and the Black wire connects to terminal 1. "name": "Davy Merino",
Is there a separate switch somewhere between breaker and timer? hi, I have a smart pump for my pool, the time clock turns on in the morning and at the same time I see that the pump has power but it doesnt turn on, I have to turn on manually, is it something that the electrician has to connect to the pump so they are synchronized? Sometimes those are looped back to the control box. A qualified person would check there is power to the timer and then bypass the timer to see if the pump worked. },
Sometimes during power surges or lightning, these will be fused together and not come apart. Move the switch and see that they separate when off, and come together when on. The pool was running on a timer. That should quiet it down. That will do it. At some time the timer was disconnected and the pump wired direct to the breakers. It should be 110V or 220V AC. Please advise. You dont have two OFF trippers, right? how should I lubricate those? My intermatic pool timer will not automatically turn on. Hello, newer pool guy here. Followed all directions and even watched YouTube troubleshooting videos. I had the exact same thing happen recently. Once you have confirmed that you timer is working you will need to adjust the timer pins to reflect the time you want your filter system to turn on and off. That way I could schedule the pump once again. Off flipper always works. This div height required for enabling the sticky sidebar. Wont power on pump but can hear timer clicking away. If you run rope/twine through the Air Pillow grommets, you can tie them to each other and run the rope/string to opposite sides of the pool, tying it off, so they will stay in the middle. Check the motor, and be sure the label is not printed 50 hz. I noticed that the on flipper was a little bit bent so I replaced it with new one. Any help is greatly appreciated. But no gears or any sound. I have the PF1202T timer on my pool. Some white lithium grease on the switch can help in some cases. The on/off pins are tight and pretty new stillany thoughts? Is that a faulty motor? Ft. 750 Joshua Dr, Hollister, CA 95023. See the wirig diagram in the owners manual here: https://www.intheswim.com/images/PDFs/E2412_Owners_Manual.pdf Clock motor power, as shown in the wiring diagram, comes from terminal 1 and also terminal 3. Clean the gears with a toothbrush if you see debris or gunk in them. not sure what is the problem. TO SET "ON" AND "OFF" TIMES: Hold trippers against edge of CLOCK-DIAL, pointing to time (AM or PM) when ON and OFF operations are desired, tighten tripper screws firmly. It is a good idea to use pliers or a wrench and reseat the trippers, then tighten them at the desired on/off times. Or other advice or explanation. HI Ben, yes just remove the OFF tripper, and the clock will always be ON. I have a 2 speed pump. If you look closely (with a flashlight and your glasses! Next step would be to inspect the wires going from timer to pump motor, or test them for continuity. The circuit is protected by two ganged breakers. Turn on / off manually work fine, but The clock gears still not moving. Shannon, compare the wiring to the diagram for Line and Load (line is power coming in, Load is power out to your pump). Thank you. Any other thoughts? "caption": "In The Swim Blog"
After a power failure the timer clock can start up backwards, mine has done this several times. I would suggest calling Intermatic and suggesting that idea and a free replacement? It worked for a day but the day after it didnt work. Hi Davey, They should be straight, if not, replace them. Or the switch can suffer wear over many years, and might not make solid contact. Its best to just write down the spots each timer is in, but remember that its a 24 hours cycle so you will need to come back within 24 hours to see if the pins moved. Luis, it will, until it is switched to OFF, or until the OFF tripper shuts it off. Now Im having to turn my pool pump on and off manually. This site is owned and operated by AJH Trade Group. It is still moving and it will trip off but not on. charging for timer($150.00) and filter cartridge replacement ($90.00) and a gasket($25.00)called bc of a hose leak, assume that is the gasket but then told that the other 2 parts are needed. Motor runs past the on dog but doesnt flip pump on? The problem lies where the power dies, youve probably heard that before. http://waterheatertimer.org/Tork-timers-and-manuals.html Replaced timer motor on a T10404R Now time is running fast about 2 hrs. The clock not turning on your Intermatic pool timer is a common issue. There is a second switch between the breaker and the timer. HI Jeff, do you have power outages sometimes? The yellow clock face should sit down in the timer. If the pump comes on, you definitely have power to the timer. I not sure if this is the best timer to use. Does the tripper work on other areas of the clock, like near the off tripper? Ideally, the switch would be placed after the timeclock, not before. We like that this pool timer because it is made from heavy-duty material and two grounded outlet makes it safe and durable. Grab it, pull it towards you, move it around then place it back down. Before using your timer to optimize your pump, you need to determine that your pool's pH, alkalinity, and calcium hardness are 7.4 to 7.6, 100 to 150 ppm, and 150 to 400 ppm, respectively. Check out the wiring diagram that comes with a new timer, or is printed on the door of the timer box. To use an analog timer, you simply need to set when you want the timer to be on and off using trippers. When I turned it back on now the pool clock goes backwards. Close. Because a pool timer is an electrical timer with mechanical aspects, the clock dial portion of the timer pulls out to set the time. I reset the breaker and tested the GCFI and I have 240V going in and out of the timer still but my pump isnt moving. Either that or if an older clock, the motor may be failing, or the switch mechanism worn (the part that is tripped by the tripper). Hi John, the trip mechanism on the clock, the switch, could be worn to the point where the tripper does not make good contact. Lately, the timer mechanism on my old T104R does not move. Karl, good question. Clock wont move, gear dont move at all. how can I turn the time bar back down to the 6 oclock point so my timer will turn the lights on some how it is in the 2 oclock position an will not turn on automatically, Your email address will not be published. #1. 2. Thank you. my pool timer the does not turn itself on only shuts off I put new trips in but still not working I dont see any ant build up inside there or anything could it just be time to replace the old girl because thats what Im thinking. I need to replace a timer for my pool vacuum. Hi Mike, yes I sent you an email to your yahoo acct. Until it came in, I manually turned on and the tripper turned it off. How to fix a Pool Pump Timer - Easy replacement using the Intermatic T104 Darren Does Everything Pool Timer Not Turning ON or OFF!! How do you know if your pool timer is bad? And when switched on, power to the load terminals? Confused. It may or may not reduce the noise level however. It sounds like the Line and Load wires are reversed. Did you find the issue? I just replaced an Intermatic WG1573-10D timer motor. To adjust the time you will first want to look for the time bar that is mounted in the middle of the timer wheel. Just above the yellow clock youll see some holes. The other gears move very slowly, and appear to not move at all, except for one I believe? MLS # 6354744 To check this, carefully inspect the gears for missing teeth and make sure they all freely turn. TO SET TIME-OF-DAY:Pull CLOCK-DIALoutward. P.S. Still no luck. Hi Jere, that could be the timer motor failing. Two days ago after my pool pump shut off automatically I decided to turn it back on because the pool was still dirty. Timer dial is not turning Breaker OFF Turn ON Power Timer motor dead due to lightning Replace timer 3. For any wiring concerns, always refer to the wiring diagram printed on the inside of the timer door. Check that the motor gears are still moving also, when it gets to the switch and the dial stops moving. Also be sure that the ON dog is not actually an OFF dog, and that it is tightly secured to the dial edge and pushed all the way onto the dial, and straight. Move the start and stop pins to appropriate times for swimming pool filter operation. I bought a new timer and replace the T104 timer clock. I have an Intermatic 277/208v T104 timer controlling two 60Hz 120v outdoor lighting circuits. I went to my houses main panel breaker and Flipped that breaker which leads to the pool panel breaker and replaced that breaker which goes straight to the timer. You can turn off Freeze protection and it should stop, or replace the probe if faulty. Hi David, I suppose that you could wire the T101 from the outlet, but Im not sure if that is in accordance with code. Sometimes the trippers get loose or damaged. There is no replacement on/off switch available, you would need a new T104 mechanism, unless you are able to melt some solder, or fix it with duct tape or something, lol! I just replaced my T101 timer 2 years ago. Hi Rhomell, are you sure you got the correct trippers? "primaryImageOfPage": {
Common timer problems include the clock not turning, not switching the pump on/off, loose timer pointer and a stopped clock. Take them off and inspect them. Hi Larry, if you can see the motor gears turning in the visual motor check, you may just need some lubrication added to the tripper mechanism. . Also I have rotated the dial several times to trip on and off hoping that it lubricates the problem lever and dusts off the coil well. "@type": "Organization",
Faulty Pump or Wiring from the Timer to the Pump. 110V or 220V? The BN-LINK compact outdoor mechanical pool pump timer is programmable in 15-minute intervals with 48 setting options in a 24 hours period. So I connected all leads as on the directions and the clock and on off manual switch working.Not sure if timer was never connected or someone disconnected it. Thank you so much. Date Listed: 18/02/2023; . 2,767 Sq. Same goes for slipping timer dogs! Can I wire this timer to an outlet or should I search for another solution? If I have to tell you which terminals to measure, you shouldnt be doing this! So if you see the 10am behind the time marker, this means that the timer has the current time of 10am. My timer clock does not run and the manual on off switch does not turn off the pump motor. The tabs on the back of the timer may have fused together, or the tabs on the stationary switch at the rear of the motor, from a power surge. Turn the power off at the breaker box and carefully remove the wires to the clock. It is a dayton time switch model 2E259 with switch rating of 40 amps, 2 HP, 250 volts AC with clock motor rating of 250 volts and 60 cycles. If I manually push the lever, it moves without much pressure. The power should run from the breaker, to the timer, to the pump. I replaced my pool timer a couple of months ago with a Tork 1109A mechanical 240v timer. We cover T101, T103 and T104 models of mechanical pool timers. Flip off the breaker. Does the motor gradually start running slowly? In this case its likely the On/Off trippers, loose wiring, the clock face not being located correctly or a faulty pump. I hope this helps. Maybe 2/wks ago I replaced it with a new timer, and it's doing the same thing. Or is there anything else I can check? Same way, WD-40 or any light lubricating oil. Learn more about pool care and repair. The timer not working is for the pump. I have the same issue currently, and it makes no sense to me so far. Turn the manual on/off switch. Second thing to check is the dial bent or warped, in that area where the on tripper is? Basically 12 real life hours equals about 14 on the timer. I visually checked the clock motor and it was good. Go for it, a little maintenance expense. Thanks again for your help. i have an oval pool that is closed for the winter but there ha been a problem. You can turn the dial and then only wait a few minutes to check is the OFF tab is working. Hi Phil, usually the OFF dog may not be fully pushed onto the dial, or if you examine it closely, it might be worn. No matter what caused the issue, there is typically an easy fix! I can turn the pool pump on via the manual power lever thats located at 5 O clock on the timer. (usually not). Or may be bent and not come together. Tork pool timer dial, spins freely, not keeping Timer is not 100% identified. I have a sweeper set on auto on the second timer and it is working correctly. "caption": "In The Swim Blog"
Turn in either direction and align the exact time-of-day on . the problem lies, where the power dies as they say. For Sale: 2 beds, 2 baths 1152 sq. The most common pool timer used for inground pool pumps is the Intermatic time clock. my pool cleaner timer dog is set between 8 am and 11 am, everything is working fine manually, except that the pool cleaning pump will not start by the timer dog setting the clock is set correctly and moving . "width": "611",
For example, sometimes you can see a burnt wire or sometimes it may be as simple as the circuit breaker has been tripped. Hi Catherine, turning it on manually should not have damaged anything, so go easy on yourself It might have just been time to go. The 2,810 sq. If all looks tight and no foreign objects or insects are found to be in there, and the switch mechanism does not look worn (the silver part next to the tab you manually flip to turn on/off), then its probably a failing timer motor. Put a meter on the wires or trace them back to find out their voltage and source. White is usually neutral (for 115V power), and black/red are usually hot, but sometimes people dont always use the correct wire color. Switch the breaker off at the power board. And does the switch look worn, where the tripper engages? But of the timer itself is bad you will need a licensed electrician to change the timer for you. Have you any suggestions at to why I am experiencing this problem? I took the electrical box cover off and check the breaker connections. To check this, try to pull out the clock dial and then move it to the correct time and press it back down again. No high loop or air gap in the old under-the-sink dishwasher drain, Consider radiant underfloor heating system, Several Important Steps Homeowners Can Take To Protect Their Furnace, 4 Kinds Of Chemical Drain Cleaners That Clear Out Drains and Their Hidden Dangers. I dont see any debris blocking the off dog. You can always call us at 815-675-7000 M-F 8am-4:30pm CST and . Hi Andy, when a clock is running slow, we might assume power outages, but when it runs fast, we might assume either a 60 hz (US) timeclock hooked up to 50 hz power service (Europe), or vice-versa, or a manufacturing defect in the gear tolerances could cause a synchronous motor timer to run fast. Second thing to check is the dial bent or warped, in that area where the on tripper is? Please let me know if you find the solution! Repeat the process for the "on" pin. Deep down, I figured it was something I did wrong and it was. Hi Tyler, maybe the dial is now pushed forward, far enough to where the trippers do not contact the switch? Much like your timer pointer, the trippers can become loose and move around as well. Thanks. Look at the copper tabs on the back and observe the action as you flip the switch manually on and off. Eldon, the breaker should not be bad, but the timeclock may be wired incorrectly. So what would be the problem? PF1202T Freeze Protection Control Parts - INYOPools.com Home Pool Parts Time Clock & Control Parts PF1202T Freeze Protection Control Free Shipping on all Orders over $49! Hi, Davy, seeing lots of complaints here. Now it worksbut its really fast. "keywords": "",
Homes similar to 2425 Glenview Dr are listed between $725K to $2M at an average of $385 per square foot. You should always be able to switch your pump on and off manually at the timer. If not, the motor may be failing. Any ideas why its doing that? Required fields are marked *. To do this, pull the yellow-faced time dial (clockface) toward you. If your pool pump timer isn't working, it's likely because of these explanations: Broken timer motor Power outage Circuit breaker problems Loose timer tags Disconnected wires Incorrect time of day Broken internal timer In this article, I'll discuss several reasons your pump's timer won't work. Pool Timer Not Turning ON or OFF!! To inspect, shut off power at the breaker, and push on the clip at the top of the box, to allow the mechanism to fall forward, and then you can inspect the vertical copper bars, and see how they shift and come apart (or not), when the switch is turned to off. Shut off the breaker and check that the wires are tight on the terminals, and that the white wires are connected well on the motor (depress the tab at the top to inspect behind the time clock). Push the tab on the top, and let the mechanism fall forward. GFCI breakers trip at a very low threshold, doesnt take much. Sometimes the circuit breaker will trip again as soon as you reset it or even trip when the pump starts running. The pump worked perfectly before I unscrewed it. 1. I have a inground pool with T10003RT4 control panel. March 16, 2022 by WildRiverCountry. The clock is powered from the Line 1 terminal correct? Yes, seen that before! "
Another thing you will need to troubleshoot and check is the circuit breaker for your pool timer. Your pool timer and pump will be on its own circuit and have a dedicated circuit breaker or GFCI (ground fault circuit interrupter). You should be able to see the gears moving. Started about a month ago and I checked the dog tripper at that time and it started working again for awhile but hasn't now for a week. If you pull out on the clock dial, you can turn it to set the current time, aligning with the silver down-arrow, located at 6 oclock. First, verify the power is turned off at the breaker panel. "@type": "ImageObject",
Pool and Spa Expert: Mike_G2010 With the switch up it is in Auto mode. "publisher": {
Replaced complete new timer assuming 5 years perfect service probably wore it out. Ill do the same. Reset the clock on the timer to the correct time to get it back to the desired on/off times. Using Your Timer to Optimize Your Pool Pump Download Article 1 Check the chemical balance of your pool. The gears in mechanical timers can get damaged. Everythings OK now, unit works just fine. My pool pump timer is not working properly. If your pool pump timer is beyond repair, call a professional to replace it. There are 2 main facets to setting the mechanical timer for a pool pump, setting the time, and setting the on/off trippers. It was always fine before. It I set the timer again it will jeep time until it gets to the next dog ear. I believe its the manual on/off switch that is the problem. Start with the easy checks. "url": "https://blog.intheswim.com/"
Ive got a weak pump battery so every time the mechanism shuts off it looses time. I realized today that my pump has been on for 11 hours, but the clock has only moved a few hours. I replaced the pump and still nothing is moving. There are many reasons why your pool timer may not be working. The 240V or the T104 models have 5 brass screws (terminals) underneath the plastic insulator cover. The A terminal is not normally used, unless you have a 3 wire service. If the switch simply does not move side to side, it may be a bad clock, if you cannot see what is stopping it from moving. It seems flimsy when I click it onOnce on, it works like it should and shuts off every time. I have replaced the trippers, but the problem persists. Secure wire conduit to the knock out with the proper conduit connectors, and first connect the green ground wire to the green ground screw labeled GRD. First you want to make sure there is actually power getting from the power board to the timer itself. The capacitor for the motor may be bad. After I replaced the motor with a 60Hz 277/208v motor the timer ran, but gained 1 hr/day. If any of these issues occur your timer will not work properly. Hi Tanya, yes that sounds like it might be wired incorrectly, check the wiring diagram on the label, or if missing, you can find them online for your timer model. Theres power to the pump using the manual override. But my new timer will not work either. The trippers will "trip" the analog clock to turn on and off automatically at the set times. The best pool timers allow you to keep your swimming pool spotless without needing to run your pump around the clock. Hi Dave, my pool timers not working but when I look in the little window I do see the largest back gear turning (possibly the yellow time plate gear as that appears to be moving..yet not keeping correct time.) "@type": "BlogPosting",
Do not remove the screws from the trippers. "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Look for any disconnected or damaged wires leading to the motor on the rear of the clock. With the breakers turned off, remove the mechanism from the box. Now ever sense I did that last week my timer wont shut off or turn on my pool pump. I see that the Intermatic WG1573-10D Replacement 208-277 VAC, 60 Hz Motor, is compatible with For use with T102, T104 and WH40 clocks by Intermatic. Did the power recently go out or has the circuit breaker tripped? I found a diagram showing neutral to A, line 1 to terminal 1 and line 2 to terminal 3. "url": "https://intheswim.com/",
The timer quit after a nearby lightning strike. Hi Davy, No luck. Also be careful not to loosen the timer pins to much or they could fall off the timer wheel and onto the ground. Reset the clock to the correct time. Hi Joe, could be time, for new timer. Almost like it doesnt have the strength to click the timer on or off. do i need to do something different? DEWENWILS Outdoor Outlet Box. Sometimes we suspect the timer is the issue but it turns out its really the pump or the wiring between the pump and the timer. In this post, we discuss a few quick and easy ways to troubleshoot your pumps Intermatic timer clock problems. Hi, the trippers are even slightly damaged the timer won't work correctly. 2nd black goes to -2 Turn the metal bar until it contacts one of two plastic side tabs. Gears are moving , clock is seated correctly and everything is wired per diagram now that pool season is here I have to manually turn my pool on and off at the timer . Wired correctly, #10 wire, nothing. On occasion the two points that are used for setting the ON and OFF times for the pool pump get damaged or loosen. This product can be controlled with your voice through Alexa-enabled devices such as Amazon Echo and Amazon Tap. It stays on until I turn off the circuit breaker. Read Book Tork Trippers Manual Guide Pdf For Free Sea Kayaking The World Almanac Road Trippers' Guide to National Parks: 5,001 Things to Do, Learn, and See for Yourself Dream Trippers The Little Road Trip Handbook Technical Manual War Department Technical Manual Canadian Mining Journal. My intermatic timer is about two years old as well. Should it still not work, I suspect a motor failure for the clock. Found the answer. I noticed that they had stopped. You need extreme care in this next step. Depends maybe on what it is getting stuck on, or what is catching the tripper, and are the motor gears still turning when it gets stuck? 20 Reasons Why Pool Pumps Lose Pressure (and what to do), 25 Ways to Keep Ducks, Geese & Birds Out of Pool. Some of the replacement motors make it past quality control with the incorrect gear setup. when the lever is in the off position the gears stop turningis this unit wired incorrectly, Natural goes to A View more property details, sales history and Zestimate data on Zillow. The green tripper is a recent thing - maybe the last 3 years they have been included in the replacement bag. Replace them if they appear to be bent. They may be fused together, or could be a lizard stuck in there, or some other foreign object or insects. You may need to adjust the meshing of the timer motor gear so it runs the clock. I would shut off power to the clock while you spray, and release the tab at the top so you can spray behind the clock, and then find the nearby nest, and dig it up and add in some ant killer granular, or other method, to get the colony to move somewhere else. Clock not turning or making any sound. Why do we stock so many pool parts? It started lagging again a week or so ago. Pool pump comes on fine with the on dog, but wont turn off. These are the trippers that came with the time clock. Is the ON tripper all the way pushed onto the dial? I looked through the visual motor check and the gear still moving fine. You could be missing the timer pins, you could have a bad timer, you could have no power to the timer or maybe even the timer is set wrong and it really is working but your not seeing it. The same happens prior to the timer reaching the off tripper. If not, that sounds like a weak/bad motor. I think I have found it. Partially loosen the screw that holds the "off" pin in place. You can manually engage it by turning it and then it will run and even SHUT OFF when its supposed to.

Louisville And Nashville Railroad Locomotives, Billy Walker Obituary Oregon, Is Smokey Robinson Still Alive, Ways Of Checking Information For Accuracy, Articles P

pool timer trippers not working